<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>HFFR Compounds Archives - Hasacom</title>
	<atom:link href="https://hasacom.com/en/urun-kategori/polymer_compounds/hffr_compounds/feed/" rel="self" type="application/rss+xml" />
	<link>https://hasacom.com/en/urun-kategori/polymer_compounds/hffr_compounds/</link>
	<description>Hasa International trade goods import and export</description>
	<lastBuildDate>Sun, 02 Nov 2025 12:19:45 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9</generator>

<image>
	<url>https://hasacom.com/en/wp-content/uploads/2023/01/cropped-favicon-1-32x32.png</url>
	<title>HFFR Compounds Archives - Hasacom</title>
	<link>https://hasacom.com/en/urun-kategori/polymer_compounds/hffr_compounds/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>HFFR Halogen-Free Flame-Retardant Jacketing Compound</title>
		<link>https://hasacom.com/en/urun/hffr-halogen-free-uv-oil-resistant-flame-retardant-jacketing-compound-lsj01-or/</link>
					<comments>https://hasacom.com/en/urun/hffr-halogen-free-uv-oil-resistant-flame-retardant-jacketing-compound-lsj01-or/#respond</comments>
		
		<dc:creator><![CDATA[Zahra Kasraei]]></dc:creator>
		<pubDate>Sat, 01 Nov 2025 17:33:18 +0000</pubDate>
				<guid isPermaLink="false">https://hasacom.com/en/?post_type=product&#038;p=1876</guid>

					<description><![CDATA[<p>LSJ01-OR is a halogen-free, UV- and oil-resistant, low-smoke, flame-retardant thermoplastic compound ... </p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-uv-oil-resistant-flame-retardant-jacketing-compound-lsj01-or/">HFFR Halogen-Free Flame-Retardant Jacketing Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<p data-start="992" data-end="1436">LSJ01-OR is a thermoplastic halogen-free compound formulated for power and control cable sheathing where weather, UV, and oil resistance are required.<br data-start="1180" data-end="1183" />It exhibits superior fire performance, smooth extrusion, and long-term durability under outdoor exposure.<br data-start="1300" data-end="1303" />The compound meets IEC 60502-1 (ST8), IEC 60092-359 (SHF1), BS 7655, VDE 0250 HM2/HM4, and EN 50575 requirements.</p>
<h3 data-start="1443" data-end="1463"><strong data-start="1447" data-end="1463">Key Features</strong></h3>
<ul data-start="1464" data-end="1725">
<li data-start="1464" data-end="1508">
<p data-start="1466" data-end="1508">Halogen-free, low smoke, flame-retardant</p>
</li>
<li data-start="1509" data-end="1563">
<p data-start="1511" data-end="1563">UV-resistant and oil-resistant for outdoor use</p>
</li>
<li data-start="1564" data-end="1605">
<p data-start="1566" data-end="1605">High tensile strength and flexibility</p>
</li>
<li data-start="1606" data-end="1644">
<p data-start="1608" data-end="1644">Excellent extrusion surface finish</p>
</li>
<li data-start="1645" data-end="1692">
<p data-start="1647" data-end="1692">Stable mechanical and electrical properties</p>
</li>
<li data-start="1693" data-end="1725">
<p data-start="1695" data-end="1725">Safe, non-hazardous compound</p>
</li>
</ul>
<h3 data-start="1732" data-end="1764"><strong data-start="1736" data-end="1764">Technical Specifications</strong></h3>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse">
<table class="w-fit min-w-(--thread-content-width)" data-start="1766" data-end="2755">
<thead data-start="1766" data-end="1808">
<tr data-start="1766" data-end="1808">
<th data-start="1766" data-end="1777" data-col-size="md">Property</th>
<th data-start="1777" data-end="1793" data-col-size="sm">Typical Value</th>
<th data-start="1793" data-end="1808" data-col-size="sm">Test Method</th>
</tr>
</thead>
<tbody data-start="1854" data-end="2755">
<tr data-start="1854" data-end="1901">
<td data-start="1854" data-end="1864" data-col-size="md">Density</td>
<td data-start="1864" data-end="1884" data-col-size="sm">1.45 ± 0.02 g/cm³</td>
<td data-start="1884" data-end="1901" data-col-size="sm">IEC 60811-1-3</td>
</tr>
<tr data-start="1902" data-end="1951">
<td data-start="1902" data-end="1921" data-col-size="md">Tensile Strength</td>
<td data-start="1921" data-end="1934" data-col-size="sm">≥ 13 N/mm²</td>
<td data-col-size="sm" data-start="1934" data-end="1951">IEC 60811-1-1</td>
</tr>
<tr data-start="1952" data-end="2001">
<td data-start="1952" data-end="1974" data-col-size="md">Elongation at Break</td>
<td data-start="1974" data-end="1984" data-col-size="sm">≥ 200 %</td>
<td data-start="1984" data-end="2001" data-col-size="sm">IEC 60811-1-1</td>
</tr>
<tr data-start="2002" data-end="2083">
<td data-start="2002" data-end="2048" data-col-size="md">Ageing (7 days @ 100 °C) ΔTensile / ΔElong.</td>
<td data-start="2048" data-end="2066" data-col-size="sm">± 40 % / ± 40 %</td>
<td data-start="2066" data-end="2083" data-col-size="sm">IEC 60811-1-2</td>
</tr>
<tr data-start="2084" data-end="2126">
<td data-start="2084" data-end="2100" data-col-size="md">Tear Strength</td>
<td data-start="2100" data-end="2110" data-col-size="sm">10 N/mm</td>
<td data-start="2110" data-end="2126" data-col-size="sm">BS 6469:99.1</td>
</tr>
<tr data-start="2127" data-end="2169">
<td data-start="2127" data-end="2138" data-col-size="md">Hardness</td>
<td data-start="2138" data-end="2155" data-col-size="sm">52 ± 2 Shore D</td>
<td data-start="2155" data-end="2169" data-col-size="sm">ASTM D2240</td>
</tr>
<tr data-start="2170" data-end="2234">
<td data-start="2170" data-end="2207" data-col-size="md">Melt Flow Index (150 °C / 21.6 kg)</td>
<td data-start="2207" data-end="2220" data-col-size="sm">3 g/10 min</td>
<td data-start="2220" data-end="2234" data-col-size="sm">ASTM D1238</td>
</tr>
<tr data-start="2235" data-end="2292">
<td data-start="2235" data-end="2263" data-col-size="md">Heat Shock (150 °C / 1 h)</td>
<td data-col-size="sm" data-start="2263" data-end="2275">No Cracks</td>
<td data-col-size="sm" data-start="2275" data-end="2292">IEC 60811-3-1</td>
</tr>
<tr data-start="2293" data-end="2365">
<td data-start="2293" data-end="2342" data-col-size="md">Oil Immersion (70 °C / 4 h) ΔTensile / ΔElong.</td>
<td data-start="2342" data-end="2360" data-col-size="sm">≤ 20 % / ≤ 40 %</td>
<td data-start="2360" data-end="2365" data-col-size="sm">—</td>
</tr>
<tr data-start="2366" data-end="2443">
<td data-start="2366" data-end="2415" data-col-size="md">UV Exposure (720 h) Retention Tensile / Elong.</td>
<td data-start="2415" data-end="2430" data-col-size="sm">86 % / 86 %</td>
<td data-start="2430" data-end="2443" data-col-size="sm">ASTM G154</td>
</tr>
<tr data-start="2444" data-end="2483">
<td data-start="2444" data-end="2459" data-col-size="md">Oxygen Index</td>
<td data-start="2459" data-end="2469" data-col-size="sm">≥ 32 %</td>
<td data-start="2469" data-end="2483" data-col-size="sm">ASTM D2863</td>
</tr>
<tr data-start="2484" data-end="2539">
<td data-start="2484" data-end="2504" data-col-size="md">pH / Conductivity</td>
<td data-col-size="sm" data-start="2504" data-end="2524">&gt; 5 / ≤ 10 µS/mm</td>
<td data-col-size="sm" data-start="2524" data-end="2539">IEC 60754-2</td>
</tr>
<tr data-start="2540" data-end="2591">
<td data-start="2540" data-end="2569" data-col-size="md">Halogen Acid Gas Evolution</td>
<td data-start="2569" data-end="2576" data-col-size="sm">0 %</td>
<td data-start="2576" data-end="2591" data-col-size="sm">IEC 60754-1</td>
</tr>
<tr data-start="2592" data-end="2629">
<td data-start="2592" data-end="2608" data-col-size="md">Smoke Density</td>
<td data-start="2608" data-end="2615" data-col-size="sm">8 %</td>
<td data-start="2615" data-end="2629" data-col-size="sm">ASTM D2843</td>
</tr>
<tr data-start="2630" data-end="2672">
<td data-start="2630" data-end="2651" data-col-size="md">Light Transmission</td>
<td data-start="2651" data-end="2659" data-col-size="sm">70 %</td>
<td data-start="2659" data-end="2672" data-col-size="sm">IEC 61034</td>
</tr>
<tr data-start="2673" data-end="2708">
<td data-start="2673" data-end="2690" data-col-size="md">Toxicity Index</td>
<td data-start="2690" data-end="2697" data-col-size="sm">1.7</td>
<td data-start="2697" data-end="2708" data-col-size="sm">NES 713</td>
</tr>
<tr data-start="2709" data-end="2755">
<td data-start="2709" data-end="2730" data-col-size="md">Cold Bend / Impact</td>
<td data-start="2730" data-end="2738" data-col-size="sm">Pass</td>
<td data-start="2738" data-end="2755" data-col-size="sm">IEC 60811-1-4</td>
</tr>
</tbody>
</table>
</div>
</div>
<h3 data-start="2762" data-end="2796"><strong data-start="2766" data-end="2796">Processing Recommendations</strong></h3>
<ul data-start="2797" data-end="3117">
<li data-start="2797" data-end="2870">
<p data-start="2799" data-end="2870">Extruder Compression Ratio: 1 : 1.2 (low shear screw recommended)</p>
</li>
<li data-start="2871" data-end="3023">
<p data-start="2873" data-end="3023">Typical Temperature Profile (°C):<br data-start="2910" data-end="2913" />Zone 1 – 130–140 | Zone 2 – 140–145 | Zone 3 – 145–150 | Zone 4 – 150–155 | Head – 160–165 | Die – 165–175</p>
</li>
<li data-start="3024" data-end="3074">
<p data-start="3026" data-end="3074">Compatible with PE/EVA-based masterbatches</p>
</li>
<li data-start="3075" data-end="3117">
<p data-start="3077" data-end="3117">Classified as non-hazardous material</p>
</li>
</ul>
<h3 data-start="3124" data-end="3144"><strong data-start="3128" data-end="3144">Applications</strong></h3>
<ul data-start="3145" data-end="3303">
<li data-start="3145" data-end="3196">
<p data-start="3147" data-end="3196">Outer sheathing of power and control cables</p>
</li>
<li data-start="3197" data-end="3254">
<p data-start="3199" data-end="3254">Outdoor LSZH cables requiring UV &amp; oil resistance</p>
</li>
<li data-start="3255" data-end="3303">
<p data-start="3257" data-end="3303">Industrial, marine, and energy cable systems</p>
</li>
</ul>
<h3 data-start="3310" data-end="3337"><strong data-start="3314" data-end="3337">Packaging &amp; Storage</strong></h3>
<p data-start="3338" data-end="3489">Supplied in 25 kg PP laminated bags (pellet form).<br data-start="3392" data-end="3395" />Store below 30 °C, away from sunlight and humidity.<br data-start="3450" data-end="3453" />Do not stack directly on the ground.</p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-uv-oil-resistant-flame-retardant-jacketing-compound-lsj01-or/">HFFR Halogen-Free Flame-Retardant Jacketing Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://hasacom.com/en/urun/hffr-halogen-free-uv-oil-resistant-flame-retardant-jacketing-compound-lsj01-or/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HFFR Halogen-Free Flame-Retardant Bedding Compound</title>
		<link>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-bedding-compound-lsb01/</link>
					<comments>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-bedding-compound-lsb01/#respond</comments>
		
		<dc:creator><![CDATA[Zahra Kasraei]]></dc:creator>
		<pubDate>Sat, 01 Nov 2025 16:43:18 +0000</pubDate>
				<guid isPermaLink="false">https://hasacom.com/en/?post_type=product&#038;p=1870</guid>

					<description><![CDATA[<p>LSB01 is a halogen-free, flame-retardant thermoplastic compound developed for cable bedding ... </p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-bedding-compound-lsb01/">HFFR Halogen-Free Flame-Retardant Bedding Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<p data-start="1001" data-end="1406">LSB01 is a polyolefin-based thermoplastic compound containing a specialized flame-retardant system that provides self-extinguishing properties without the release of halogen acids.<br data-start="1215" data-end="1218" />It significantly reduces smoke, toxicity, and corrosive gas emissions, making it suitable for use in public buildings, transportation, tunnels, and high-safety cable installations.</p>
<p data-start="1408" data-end="1449">Complies with: IEC 60502 Type ST8</p>
<p data-start="1451" data-end="1471">Color: Natural</p>
<h3 data-start="1478" data-end="1498"><strong data-start="1482" data-end="1498">Key Features</strong></h3>
<ul data-start="1499" data-end="1777">
<li data-start="1499" data-end="1538">
<p data-start="1501" data-end="1538">Halogen-free and low smoke emission</p>
</li>
<li data-start="1539" data-end="1588">
<p data-start="1541" data-end="1588">Excellent self-extinguishing fire performance</p>
</li>
<li data-start="1589" data-end="1635">
<p data-start="1591" data-end="1635">Stable extrusion and smooth surface finish</p>
</li>
<li data-start="1636" data-end="1678">
<p data-start="1638" data-end="1678">Good flexibility and impact resistance</p>
</li>
<li data-start="1679" data-end="1744">
<p data-start="1681" data-end="1744">Low water absorption and no cracks after heat or cold testing</p>
</li>
<li data-start="1745" data-end="1777">
<p data-start="1747" data-end="1777">Safe, non-hazardous compound</p>
</li>
</ul>
<h3 data-start="1784" data-end="1816"><strong data-start="1788" data-end="1816">Technical Specifications</strong></h3>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse">
<table class="w-fit min-w-(--thread-content-width)" data-start="1818" data-end="2568">
<thead data-start="1818" data-end="1860">
<tr data-start="1818" data-end="1860">
<th data-start="1818" data-end="1829" data-col-size="sm">Property</th>
<th data-start="1829" data-end="1845" data-col-size="sm">Typical Value</th>
<th data-start="1845" data-end="1860" data-col-size="sm">Test Method</th>
</tr>
</thead>
<tbody data-start="1906" data-end="2568">
<tr data-start="1906" data-end="1965">
<td data-start="1906" data-end="1916" data-col-size="sm">Density</td>
<td data-start="1916" data-end="1936" data-col-size="sm">1.49 ± 0.03 g/cm³</td>
<td data-start="1936" data-end="1965" data-col-size="sm">ASTM D792 / IEC 60811-1-3</td>
</tr>
<tr data-start="1966" data-end="2014">
<td data-start="1966" data-end="1985" data-col-size="sm">Tensile Strength</td>
<td data-start="1985" data-end="1997" data-col-size="sm">≥ 9 N/mm²</td>
<td data-start="1997" data-end="2014" data-col-size="sm">IEC 60811-1-1</td>
</tr>
<tr data-start="2015" data-end="2064">
<td data-start="2015" data-end="2037" data-col-size="sm">Elongation at Break</td>
<td data-start="2037" data-end="2047" data-col-size="sm">≥ 125 %</td>
<td data-start="2047" data-end="2064" data-col-size="sm">IEC 60811-1-1</td>
</tr>
<tr data-start="2065" data-end="2128">
<td data-start="2065" data-end="2103" data-col-size="sm">Ageing Variation (7 days at 100 °C)</td>
<td data-start="2103" data-end="2111" data-col-size="sm">±40 %</td>
<td data-start="2111" data-end="2128" data-col-size="sm">IEC 60811-1-2</td>
</tr>
<tr data-start="2129" data-end="2171">
<td data-start="2129" data-end="2140" data-col-size="sm">Hardness</td>
<td data-start="2140" data-end="2157" data-col-size="sm">55 ± 1 Shore D</td>
<td data-start="2157" data-end="2171" data-col-size="sm">ASTM D2240</td>
</tr>
<tr data-start="2172" data-end="2242">
<td data-start="2172" data-end="2209" data-col-size="sm">Melt Flow Index (150 °C / 21.6 kg)</td>
<td data-start="2209" data-end="2228" data-col-size="sm">2 ± 0.5 g/10 min</td>
<td data-start="2228" data-end="2242" data-col-size="sm">ASTM D1238</td>
</tr>
<tr data-start="2243" data-end="2301">
<td data-start="2243" data-end="2272" data-col-size="sm">Heat Shock (1 h at 150 °C)</td>
<td data-start="2272" data-end="2284" data-col-size="sm">No Cracks</td>
<td data-start="2284" data-end="2301" data-col-size="sm">IEC 60811-3-1</td>
</tr>
<tr data-start="2302" data-end="2352">
<td data-start="2302" data-end="2321" data-col-size="sm">Water Absorption</td>
<td data-start="2321" data-end="2335" data-col-size="sm">≤ 10 mg/cm²</td>
<td data-start="2335" data-end="2352" data-col-size="sm">IEC 60811-1-3</td>
</tr>
<tr data-start="2353" data-end="2392">
<td data-start="2353" data-end="2368" data-col-size="sm">Cold Bending</td>
<td data-start="2368" data-end="2375" data-col-size="sm">Pass</td>
<td data-start="2375" data-end="2392" data-col-size="sm">IEC 60811-1-4</td>
</tr>
<tr data-start="2393" data-end="2431">
<td data-start="2393" data-end="2407" data-col-size="sm">Cold Impact</td>
<td data-start="2407" data-end="2414" data-col-size="sm">Pass</td>
<td data-start="2414" data-end="2431" data-col-size="sm">IEC 60811-1-4</td>
</tr>
<tr data-start="2432" data-end="2470">
<td data-start="2432" data-end="2447" data-col-size="sm">Oxygen Index</td>
<td data-start="2447" data-end="2456" data-col-size="sm">≥ 30 %</td>
<td data-start="2456" data-end="2470" data-col-size="sm">ASTM D2863</td>
</tr>
<tr data-start="2471" data-end="2527">
<td data-start="2471" data-end="2491" data-col-size="sm">pH / Conductivity</td>
<td data-start="2491" data-end="2512" data-col-size="sm">&gt; 4.3 / ≤ 10 µS/mm</td>
<td data-start="2512" data-end="2527" data-col-size="sm">IEC 60754-2</td>
</tr>
<tr data-start="2528" data-end="2568">
<td data-start="2528" data-end="2543" data-col-size="sm">Flame Spread</td>
<td data-start="2543" data-end="2553" data-col-size="sm">&gt; 50 mm</td>
<td data-start="2553" data-end="2568" data-col-size="sm">IEC 60332-1</td>
</tr>
</tbody>
</table>
</div>
</div>
<h3 data-start="2575" data-end="2609"><strong data-start="2579" data-end="2609">Processing Recommendations</strong></h3>
<p data-start="2610" data-end="2878">Typical extrusion temperature zones (°C):<br data-start="2651" data-end="2654" />Zone 1 – 130–150 | Zone 2 – 130–160 | Zone 3 – 140–160 | Zone 4 – 140–160 | Head – 150–170 | Die – 150–170<br data-start="2760" data-end="2763" />Drawdown ratio: 1.2–1.8  L/D ratio ≈ 22<br data-start="2802" data-end="2805" />Use low-shear screws and controlled line speeds for best surface quality.</p>
<h3 data-start="2885" data-end="2905"><strong data-start="2889" data-end="2905">Applications</strong></h3>
<ul data-start="2906" data-end="3085">
<li data-start="2906" data-end="2949">
<p data-start="2908" data-end="2949">Bedding and filler layer in LSZH cables</p>
</li>
<li data-start="2950" data-end="3017">
<p data-start="2952" data-end="3017">Power and control cables requiring halogen-free fire protection</p>
</li>
<li data-start="3018" data-end="3085">
<p data-start="3020" data-end="3085">Building, industrial, marine, and public infrastructure cabling</p>
</li>
</ul>
<h3 data-start="3092" data-end="3119"><strong data-start="3096" data-end="3119">Packaging &amp; Storage</strong></h3>
<p data-start="3120" data-end="3270">Supplied in 25 kg PP laminated bags in pellet form.<br data-start="3175" data-end="3178" />Store below 30 °C, away from direct sunlight and moisture.<br data-start="3240" data-end="3243" />Keep bags sealed until use.</p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-bedding-compound-lsb01/">HFFR Halogen-Free Flame-Retardant Bedding Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-bedding-compound-lsb01/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HFFR Halogen-Free Thermoplastic Jacketing Compound</title>
		<link>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-jacketing-compound-lsj01/</link>
					<comments>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-jacketing-compound-lsj01/#respond</comments>
		
		<dc:creator><![CDATA[Zahra Kasraei]]></dc:creator>
		<pubDate>Sat, 01 Nov 2025 16:13:38 +0000</pubDate>
				<guid isPermaLink="false">https://hasacom.com/en/?post_type=product&#038;p=1866</guid>

					<description><![CDATA[<p>LSJ01 is a halogen-free, low-smoke, flame-retardant thermoplastic compound designed for cable ... </p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-jacketing-compound-lsj01/">HFFR Halogen-Free Thermoplastic Jacketing Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<p data-start="990" data-end="1386">LSJ01 is a halogen-free, flame-retardant compound formulated for the outer sheathing of power and control cables.<br data-start="1137" data-end="1140" />It offers excellent processability, mechanical strength, UV resistance, and fire safety.<br data-start="1236" data-end="1239" />The compound is suitable for both indoor and outdoor LSZH (Low Smoke Zero Halogen) cable systems and complies with key international standards.</p>
<p data-start="1388" data-end="1415"><strong data-start="1388" data-end="1413">Applicable Standards: </strong>IEC 60502-1 Type ST8 | IEC 60092-359 Type SHF1 | BS 7655:6.1 | DIN VDE 0207 / 0250 HM2-HM4 | BS EN 50575</p>
<h3 data-start="1536" data-end="1556"><strong data-start="1540" data-end="1556">Key Features</strong></h3>
<ul data-start="1557" data-end="1821">
<li data-start="1557" data-end="1594">
<p data-start="1559" data-end="1594">Halogen-Free and Low Smoke (LSZH)</p>
</li>
<li data-start="1595" data-end="1647">
<p data-start="1597" data-end="1647">Excellent Flame Retardancy (Oxygen Index ≥ 32 %)</p>
</li>
<li data-start="1648" data-end="1684">
<p data-start="1650" data-end="1684">UV Resistance for Outdoor Cables</p>
</li>
<li data-start="1685" data-end="1729">
<p data-start="1687" data-end="1729">High Flexibility and Mechanical Strength</p>
</li>
<li data-start="1730" data-end="1773">
<p data-start="1732" data-end="1773">No Cracks under Heat or Cold Conditions</p>
</li>
<li data-start="1774" data-end="1821">
<p data-start="1776" data-end="1821">Excellent Surface Finish and Easy Extrusion</p>
</li>
</ul>
<h3 data-start="1828" data-end="1860"><strong data-start="1832" data-end="1860">Technical Specifications</strong></h3>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse">
<table class="w-fit min-w-(--thread-content-width)" data-start="1862" data-end="2813">
<thead data-start="1862" data-end="1904">
<tr data-start="1862" data-end="1904">
<th data-start="1862" data-end="1873" data-col-size="md">Property</th>
<th data-start="1873" data-end="1889" data-col-size="sm">Typical Value</th>
<th data-start="1889" data-end="1904" data-col-size="sm">Test Method</th>
</tr>
</thead>
<tbody data-start="1951" data-end="2813">
<tr data-start="1951" data-end="1998">
<td data-start="1951" data-end="1961" data-col-size="md">Density</td>
<td data-col-size="sm" data-start="1961" data-end="1981">1.45 ± 0.02 g/cm³</td>
<td data-col-size="sm" data-start="1981" data-end="1998">IEC 60811-601</td>
</tr>
<tr data-start="1999" data-end="2048">
<td data-start="1999" data-end="2018" data-col-size="md">Tensile Strength</td>
<td data-start="2018" data-end="2031" data-col-size="sm">≥ 12 N/mm²</td>
<td data-start="2031" data-end="2048" data-col-size="sm">IEC 60811-1-1</td>
</tr>
<tr data-start="2049" data-end="2098">
<td data-start="2049" data-end="2071" data-col-size="md">Elongation at Break</td>
<td data-col-size="sm" data-start="2071" data-end="2081">≥ 175 %</td>
<td data-col-size="sm" data-start="2081" data-end="2098">IEC 60811-1-1</td>
</tr>
<tr data-start="2099" data-end="2187">
<td data-start="2099" data-end="2154" data-col-size="md">Ageing (7 days at 100 °C) – Δ Tensile / Δ Elongation</td>
<td data-col-size="sm" data-start="2154" data-end="2170">±30 % / ±30 %</td>
<td data-col-size="sm" data-start="2170" data-end="2187">IEC 60811-1-2</td>
</tr>
<tr data-start="2188" data-end="2229">
<td data-start="2188" data-end="2204" data-col-size="md">Tear Strength</td>
<td data-col-size="sm" data-start="2204" data-end="2213">8 N/mm</td>
<td data-col-size="sm" data-start="2213" data-end="2229">BS 6469:99.1</td>
</tr>
<tr data-start="2230" data-end="2272">
<td data-start="2230" data-end="2241" data-col-size="md">Hardness</td>
<td data-start="2241" data-end="2258" data-col-size="sm">55 ± 1 Shore D</td>
<td data-col-size="sm" data-start="2258" data-end="2272">ASTM D2240</td>
</tr>
<tr data-start="2273" data-end="2329">
<td data-start="2273" data-end="2298" data-col-size="md">MFI (150 °C / 21.6 kg)</td>
<td data-start="2298" data-end="2315" data-col-size="sm">7 ± 1 g/10 min</td>
<td data-col-size="sm" data-start="2315" data-end="2329">ASTM D1238</td>
</tr>
<tr data-start="2330" data-end="2388">
<td data-start="2330" data-end="2359" data-col-size="md">Heat Shock (1 h at 150 °C)</td>
<td data-col-size="sm" data-start="2359" data-end="2371">No Cracks</td>
<td data-col-size="sm" data-start="2371" data-end="2388">IEC 60811-3-1</td>
</tr>
<tr data-start="2389" data-end="2468">
<td data-start="2389" data-end="2441" data-col-size="md">UV Exposure (720 h) Retained Tensile / Elongation</td>
<td data-col-size="sm" data-start="2441" data-end="2455">86 % / 86 %</td>
<td data-col-size="sm" data-start="2455" data-end="2468">ASTM G154</td>
</tr>
<tr data-start="2469" data-end="2518">
<td data-start="2469" data-end="2492" data-col-size="md">Hot Pressure (90 °C)</td>
<td data-col-size="sm" data-start="2492" data-end="2501">≤ 30 %</td>
<td data-col-size="sm" data-start="2501" data-end="2518">IEC 60811-3-1</td>
</tr>
<tr data-start="2519" data-end="2564">
<td data-start="2519" data-end="2540" data-col-size="md">Cold Bend / Impact</td>
<td data-start="2540" data-end="2547" data-col-size="sm">Pass</td>
<td data-start="2547" data-end="2564" data-col-size="sm">IEC 60811-1-4</td>
</tr>
<tr data-start="2565" data-end="2603">
<td data-start="2565" data-end="2580" data-col-size="md">Oxygen Index</td>
<td data-start="2580" data-end="2589" data-col-size="sm">≥ 32 %</td>
<td data-start="2589" data-end="2603" data-col-size="sm">ASTM D2863</td>
</tr>
<tr data-start="2604" data-end="2660">
<td data-start="2604" data-end="2624" data-col-size="md">pH / Conductivity</td>
<td data-start="2624" data-end="2645" data-col-size="sm">&gt; 4.3 / ≤ 10 µS/mm</td>
<td data-start="2645" data-end="2660" data-col-size="sm">IEC 60754-2</td>
</tr>
<tr data-start="2661" data-end="2701">
<td data-start="2661" data-end="2680" data-col-size="md">Halogen Acid Gas</td>
<td data-start="2680" data-end="2686" data-col-size="sm">0 %</td>
<td data-start="2686" data-end="2701" data-col-size="sm">IEC 60754-1</td>
</tr>
<tr data-start="2702" data-end="2738">
<td data-start="2702" data-end="2718" data-col-size="md">Smoke Density</td>
<td data-start="2718" data-end="2724" data-col-size="sm">8 %</td>
<td data-col-size="sm" data-start="2724" data-end="2738">ASTM D2843</td>
</tr>
<tr data-start="2739" data-end="2773">
<td data-start="2739" data-end="2756" data-col-size="md">Toxicity Index</td>
<td data-start="2756" data-end="2762" data-col-size="sm">1.7</td>
<td data-start="2762" data-end="2773" data-col-size="sm">NES 713</td>
</tr>
<tr data-start="2774" data-end="2813">
<td data-start="2774" data-end="2789" data-col-size="md">Flame Spread</td>
<td data-col-size="sm" data-start="2789" data-end="2798">&gt; 5 mm</td>
<td data-col-size="sm" data-start="2798" data-end="2813">IEC 60332-1</td>
</tr>
</tbody>
</table>
</div>
</div>
<h3 data-start="2820" data-end="2854"><strong data-start="2824" data-end="2854">Processing Recommendations</strong></h3>
<ul data-start="2855" data-end="3160">
<li data-start="2855" data-end="2935">
<p data-start="2857" data-end="2935">Use low-compression (1:1.2), low-shear screws for optimal extrusion.</p>
</li>
<li data-start="2936" data-end="3065">
<p data-start="2938" data-end="3065">Typical temperature profile (°C):<br data-start="2971" data-end="2974" />Zone 1 – 130-140 | Zone 2 – 140-145 | Zone 3 – 145-150 | Head – 155-165 | Die – 165-175</p>
</li>
<li data-start="3066" data-end="3116">
<p data-start="3068" data-end="3116">Suitable for PE/EVA masterbatch colorants.</p>
</li>
<li data-start="3117" data-end="3160">
<p data-start="3119" data-end="3160">Classified as non-hazardous material.</p>
</li>
</ul>
<h3 data-start="3167" data-end="3187"><strong data-start="3171" data-end="3187">Applications</strong></h3>
<ul data-start="3188" data-end="3365">
<li data-start="3188" data-end="3239">
<p data-start="3190" data-end="3239">Outer sheathing of power and control cables</p>
</li>
<li data-start="3240" data-end="3285">
<p data-start="3242" data-end="3285">Indoor and outdoor LSZH cable jackets</p>
</li>
<li data-start="3286" data-end="3365">
<p data-start="3288" data-end="3365">UV-resistant cable systems for industrial, marine, and building sectors</p>
</li>
</ul>
<h3 data-start="3372" data-end="3399"><strong data-start="3376" data-end="3399">Packaging &amp; Storage</strong></h3>
<p data-start="3400" data-end="3537">Supplied in 25 kg PP laminated bags.<br data-start="3440" data-end="3443" />Store below 30 °C, away from sunlight and humidity.<br data-start="3498" data-end="3501" />Do not stack directly on the ground.</p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-jacketing-compound-lsj01/">HFFR Halogen-Free Thermoplastic Jacketing Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-jacketing-compound-lsj01/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
		<item>
		<title>HFFR Halogen-Free Thermoplastic Insulation Compound</title>
		<link>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-compound-lsi01/</link>
					<comments>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-compound-lsi01/#respond</comments>
		
		<dc:creator><![CDATA[Zahra Kasraei]]></dc:creator>
		<pubDate>Sat, 01 Nov 2025 15:45:11 +0000</pubDate>
				<guid isPermaLink="false">https://hasacom.com/en/?post_type=product&#038;p=1853</guid>

					<description><![CDATA[<p>LSI01 is a halogen-free, low-smoke, flame-retardant thermoplastic compound for cable insulation ... </p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-compound-lsi01/">HFFR Halogen-Free Thermoplastic Insulation Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></description>
										<content:encoded><![CDATA[<p data-start="883" data-end="1295">LSI01 is a thermoplastic, halogen-free compound developed for low-voltage and building wire insulation requiring low smoke emission and zero halogen gas release.<br data-start="1074" data-end="1077" />The compound exhibits high flexibility, excellent surface finish, and smooth extrusion performance.<br data-start="1176" data-end="1179" />It complies with major standards such as IEC 60502-1 (ST8), IEC 60092-359 (SHF1) and BS 7655 LTS1-LTS4.</p>
<p data-start="1297" data-end="1316"><strong data-start="1297" data-end="1314">Key Features:</strong></p>
<ul data-start="1317" data-end="1604">
<li data-start="1317" data-end="1356">
<p data-start="1319" data-end="1356">Halogen-free and low smoke emission</p>
</li>
<li data-start="1357" data-end="1413">
<p data-start="1359" data-end="1413">Flame-retardant with excellent oxygen index (≥ 32 %)</p>
</li>
<li data-start="1414" data-end="1458">
<p data-start="1416" data-end="1458">High mechanical strength and flexibility</p>
</li>
<li data-start="1459" data-end="1506">
<p data-start="1461" data-end="1506">Excellent electrical insulation performance</p>
</li>
<li data-start="1507" data-end="1549">
<p data-start="1509" data-end="1549">Smooth extrusion and easy colorability</p>
</li>
<li data-start="1550" data-end="1604">
<p data-start="1552" data-end="1604">Complies with IEC, BS, and VDE standards</p>
</li>
</ul>
<p data-start="1606" data-end="1637"><strong data-start="1606" data-end="1635">Technical Specifications:</strong></p>
<div class="_tableContainer_1rjym_1">
<div class="group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse">
<table class="w-fit min-w-(--thread-content-width)" data-start="1638" data-end="2290">
<thead data-start="1638" data-end="1680">
<tr data-start="1638" data-end="1680">
<th data-start="1638" data-end="1649" data-col-size="sm">Property</th>
<th data-start="1649" data-end="1665" data-col-size="sm">Typical Value</th>
<th data-start="1665" data-end="1680" data-col-size="sm">Test Method</th>
</tr>
</thead>
<tbody data-start="1727" data-end="2290">
<tr data-start="1727" data-end="1774">
<td data-start="1727" data-end="1737" data-col-size="sm">Density</td>
<td data-col-size="sm" data-start="1737" data-end="1757">1.46 ± 0.02 g/cm³</td>
<td data-col-size="sm" data-start="1757" data-end="1774">IEC 60811-1-3</td>
</tr>
<tr data-start="1775" data-end="1824">
<td data-start="1775" data-end="1794" data-col-size="sm">Tensile Strength</td>
<td data-start="1794" data-end="1807" data-col-size="sm">≥ 13 N/mm²</td>
<td data-start="1807" data-end="1824" data-col-size="sm">IEC 60811-1-1</td>
</tr>
<tr data-start="1825" data-end="1874">
<td data-start="1825" data-end="1847" data-col-size="sm">Elongation at Break</td>
<td data-col-size="sm" data-start="1847" data-end="1857">≥ 200 %</td>
<td data-col-size="sm" data-start="1857" data-end="1874">IEC 60811-1-1</td>
</tr>
<tr data-start="1875" data-end="1916">
<td data-start="1875" data-end="1891" data-col-size="sm">Tear Strength</td>
<td data-col-size="sm" data-start="1891" data-end="1900">8 N/mm</td>
<td data-col-size="sm" data-start="1900" data-end="1916">BS 6469:99.1</td>
</tr>
<tr data-start="1917" data-end="1961">
<td data-start="1917" data-end="1938" data-col-size="sm">Hardness (Shore D)</td>
<td data-col-size="sm" data-start="1938" data-end="1947">54 ± 2</td>
<td data-col-size="sm" data-start="1947" data-end="1961">ASTM D2240</td>
</tr>
<tr data-start="1962" data-end="2030">
<td data-start="1962" data-end="1999" data-col-size="sm">Melt Flow Index (150 °C / 21.6 kg)</td>
<td data-col-size="sm" data-start="1999" data-end="2016">5 ± 1 g/10 min</td>
<td data-col-size="sm" data-start="2016" data-end="2030">ASTM D1238</td>
</tr>
<tr data-start="2031" data-end="2069">
<td data-start="2031" data-end="2046" data-col-size="sm">Oxygen Index</td>
<td data-col-size="sm" data-start="2046" data-end="2055">≥ 32 %</td>
<td data-col-size="sm" data-start="2055" data-end="2069">ASTM D2863</td>
</tr>
<tr data-start="2070" data-end="2119">
<td data-start="2070" data-end="2098" data-col-size="sm">Halogen Acid Gas Emission</td>
<td data-col-size="sm" data-start="2098" data-end="2104">0 %</td>
<td data-col-size="sm" data-start="2104" data-end="2119">IEC 60754-1</td>
</tr>
<tr data-start="2120" data-end="2156">
<td data-start="2120" data-end="2136" data-col-size="sm">Smoke Density</td>
<td data-start="2136" data-end="2142" data-col-size="sm">8 %</td>
<td data-col-size="sm" data-start="2142" data-end="2156">ASTM D2843</td>
</tr>
<tr data-start="2157" data-end="2191">
<td data-start="2157" data-end="2174" data-col-size="sm">Toxicity Index</td>
<td data-start="2174" data-end="2180" data-col-size="sm">1.7</td>
<td data-start="2180" data-end="2191" data-col-size="sm">NES 713</td>
</tr>
<tr data-start="2192" data-end="2241">
<td data-start="2192" data-end="2215" data-col-size="sm">Hot Pressure (90 °C)</td>
<td data-start="2215" data-end="2224" data-col-size="sm">≤ 30 %</td>
<td data-start="2224" data-end="2241" data-col-size="sm">IEC 60811-3-1</td>
</tr>
<tr data-start="2242" data-end="2290">
<td data-start="2242" data-end="2266" data-col-size="sm">Cold Bending / Impact</td>
<td data-col-size="sm" data-start="2266" data-end="2273">Pass</td>
<td data-col-size="sm" data-start="2273" data-end="2290">IEC 60811-1-4</td>
</tr>
</tbody>
</table>
</div>
</div>
<p data-start="2292" data-end="2325"><strong data-start="2292" data-end="2323">Processing Recommendations:</strong></p>
<ul data-start="2326" data-end="2616">
<li data-start="2326" data-end="2381">
<p data-start="2328" data-end="2381">Recommended extruder compression ratio: 1 : 1.2</p>
</li>
<li data-start="2382" data-end="2507">
<p data-start="2384" data-end="2507">Typical extrusion temperature profile (°C):<br data-start="2427" data-end="2430" />Zone 1: 130–140 | Zone 2: 140–145 | Zone 3: 145–160 | Head / Die: 155–170</p>
</li>
<li data-start="2508" data-end="2571">
<p data-start="2510" data-end="2571">Use low-shear, low-compression screws for best results.</p>
</li>
<li data-start="2572" data-end="2616">
<p data-start="2574" data-end="2616">Colorable with PE/EVA-based masterbatches.</p>
</li>
</ul>
<p data-start="2618" data-end="2637"><strong data-start="2618" data-end="2635">Applications:</strong></p>
<ul data-start="2638" data-end="2771">
<li data-start="2638" data-end="2676">
<p data-start="2640" data-end="2676">Power and control cable insulation</p>
</li>
<li data-start="2677" data-end="2721">
<p data-start="2679" data-end="2721">Building and indoor wiring (HFFR / LSZH)</p>
</li>
<li data-start="2722" data-end="2771">
<p data-start="2724" data-end="2771">Marine and industrial low-smoke cable systems</p>
</li>
</ul>
<p data-start="2773" data-end="2948"><strong data-start="2773" data-end="2797">Packaging &amp; Storage:</strong><br data-start="2797" data-end="2800" />Supplied as pellets in 25 kg PP laminated bags.<br data-start="2851" data-end="2854" />Store below 30 °C, away from sunlight and humidity.<br data-start="2909" data-end="2912" />Do not stack directly on the ground.</p>
<p><a href="https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-compound-lsi01/">HFFR Halogen-Free Thermoplastic Insulation Compound</a> yazısı ilk önce <a href="https://hasacom.com/en">Hasacom</a> üzerinde ortaya çıktı.</p>
]]></content:encoded>
					
					<wfw:commentRss>https://hasacom.com/en/urun/hffr-halogen-free-flame-retardant-thermoplastic-compound-lsi01/feed/</wfw:commentRss>
			<slash:comments>0</slash:comments>
		
		
			</item>
	</channel>
</rss>
