XLP13 is a pre-grafted polyethylene compound intended for moisture-cure crosslinking in cable insulation.
When mixed with 5 % of its catalyst masterbatch CAT13N, it forms a high-quality XLPE insulation layer with excellent thermal and electrical properties.
This compound is ideal for low-voltage power and control cables (up to 1 kV) and is compatible with high-speed extrusion lines.
Key Features
Natural XLPE compound for LV cable insulation
Excellent electrical resistivity and mechanical strength
Smooth surface finish and stable extrusion behavior
Long-term ageing resistance at 135 °C
Complies with BS 7870-5, IEC 60502-1
Technical Specifications
| Property | Typical Value | Standard |
|---|---|---|
| Melt Flow Index (190 °C / 5 kg) | 3.5 ± 0.5 g/10 min | ASTM D1238 |
| Density | 0.92 ± 0.005 g/cm³ | ASTM D792 |
| Tensile Strength | ≥ 20 N/mm² | IEC 60811-1-1 |
| Elongation at Break | ≥ 500 % | IEC 60811-1-1 |
| Ageing (7 days @ 135 °C) Δ Tensile / Δ Elongation | ≤ 25 % / ≤ 25 % | IEC 60811-1-2 |
| Hot-Set Test (200 °C, 0.2 MPa) | Elong. ≤ 100 %, Perm. ≤ 10 % | IEC 60811-2-1 |
| Volume Resistivity (23 °C) | ≥ 10¹⁶ Ω·cm | ASTM D257 |
| Water Absorption (85 °C) | ≤ 1 mg/cm³ | IEC 60502-2 |
| Shrinkage (130 °C, 1 hr) | ≤ 4 % | IEC 60502-2 |
Processing Guidelines
Mix XLP13 + CAT13N in a 95:5 ratio at room temperature just before extrusion.
Extrusion zones: 140 – 190 °C (typical).
Crosslinking methods
Hot water 90 °C × 2–6 h
Steam 6–15 h
Applications
Insulation of low-voltage power and control cables
Suitable for XLPE insulation lines and continuous extrusion
Packaging & Storage
Supplied as pellets in 25 kg aluminum multilayer bags.
Store below 35 °C in dry conditions; use within 6 months and within 4 hours after opening.










Reviews